Roto E-Tec Control
Wired sensors for security technology and room climate
- Security technology
- Ventilation and temperature control
- Extractor fan controller
- Deadbolt switch contacts
Roto E-Tec Control contact elements support windows and doors directly with management and control tasks, which ensure that a home enjoys greater security, comfort and energy efficiency. They serve as the basis for intelligent and thereby efficient building automation systems.
MVS
Security technology with Roto E-Tec Control | MVS
The magnetic locking and opening monitoring system Roto E-Tec Control | MVS provides individual solutions for break-in and danger avoidance.
The system monitors the status of the window or sliding element. As soon as the magnetic field of the MVS is disturbed, the concealed contact element sends a signal to the alarm control panel.
Technical data Roto E-Tec Control | MVS contact element
Screwed-on | Concealed | ||
Frame material | Timber, PVC, aluminium | Timber, PVC | |
---|---|---|---|
Hardware systems |
| ||
VdS approval | Class B and Class C | Class B and Class C | |
EN approval | Grade 2 and Grade 3 | Grade 2 and Grade 3 | |
Types of monitoring | Opening, locking and combined opening and locking monitoring | Opening, locking and combined opening and locking monitoring | |
IP rating | IP67 | IP67 |
MTS
Ventilation and temperature control with Roto E-Tec Control | MTS
Heat loss during the heating period can be effectively reduced with the Roto E-Tec Control | MTS magnetic thermostat sensor concealed in the window rebate. As soon as the window or sliding element is opened, the sensor ensures together with a control system provided by the customer that the heating output is automatically reduced or the air conditioner is switched off.
After the window is closed, the restored magnetic contact signals that the heating can switch into the normal temperature again.
Technical data Roto E-Tec Control | MTS contact element
Screwed-on | Concealed | ||
Frame material | Timber, PVC, aluminium | Timber, PVC | |
---|---|---|---|
Hardware systems |
| ||
Types of monitoring | Opening, locking and combined opening and locking monitoring | Opening, locking and combined opening and locking monitoring | |
IP rating | IP67 | IP67 |
DAS
Extractor fan control with Roto E-Tec Control | DAS
The Roto E-Tec Control | DAS extractor fan controller controls the proper use of an extractor fan.
With open flame, e.g. fireplaces or gas single-storey heating systems, the extractor fan in the kitchen may only be switched on when a window is open. If all windows are closed, the DAS automatically interrupts the power supply, preventing a possible danger of suffocation from carbon monoxide.
Technical data Roto E-Tec Control | DAS
Frame material | Timber, PVC |
---|---|
Hardware systems | Roto NX and Roto NT |
Approval | DIBt (only applies when enclosed magnetic switch set is used) |
Switching capacity | 230 V AC, 6 A, 1400 W, one-pin |
Deadbolt switch contacts
Roto Safe | Deadbolt switch contacts
A deadbolt switch contact is used for locking monitoring on multipoint lockings. It is an electrical switch contact which is built into the frame component and is actuated by the main deadbolt or the Roto Safe C | Tandeo additional locking.
Technical data Roto Safe | Deadbolt switch contacts
Frame material | Timber, PVC, aluminium |
---|---|
Hardware systems | Roto Safe multi-point locking systems |
VdS approval | Class C |
Type of monitoring | Locking monitoring |
IP rating | IP 67 in accordance with DIN 40050 |
Do you have any questions about the product?
Wilhelm-Frank-Platz 1
70771 Leinfelden-Echterdingen
Germany